Cloud LM-2 Series Betriebsanweisung Seite 9

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 8
Z4-8MK3 Installation and User Guide 9
Description of rear panel
10
11
12
1
13
14 16
3 6 9 15
24
5 5 87
Note - The rear panel of the Z8MK3 is shown above. The Z4MK3s is identical, except that it only has output connections for
Zones 1 - 4.
1. LINE INPUTS – 6 pairs of RCA (phono) sockets (Line 1 to Line 6) for connection of music sources. Inputs are
stereo, summed internally to mono. See page 10.
2. LINE INPUT GAIN – preset trim control for each input, providing ±10 dB of gain adjustment for input level matching.
See page 15.
3. MIC INPUTS – 2 balanced microphone inputs (Mic 1 & Mic 2) on 3-pin 3.81 mm-pitch screw-terminal connectors.
See page 11.
4. MIC GAIN – preset mic gain control for each input, gain range 10 to 60 dB. See page 15.
5. MIC EQ – HF & LF preset EQ controls. See page 15.
6. PAGING MIC INPUT – dedicated balanced input (3-pin 3.5 mm-pitch screw-terminal connector) for paging mic. See
page 12.
7. PAGING MIC GAIN – as [4]. See page 16.
8. PAGING MIC EQ – as [5]. See page 16.
9. PAGING MIC ACCESS PORT – 6-pin (Z4MK3) or 10-pin (Z8MK3) 5 mm-pitch screw-terminal connector for per-
zone contact closure paging access. See page 12.
10. ZONE OUTPUTS – 8 balanced outputs* for each zone on 3-pin 3.5 mm-pitch screw-terminal connector.
See page 11.
11. ZONE EQ – HF & LF EQ adjustment for each zone output. See page 16.
12. FACILITY PORT – 8-pin RJ45 per-zone, for connection of remote input modules and other functions. See page 12.
13. REMOTE SOURCE + LEVEL PORTS 3-pin 5 mm-pitch screw terminal connector per-zone, for connection of
RL-1/RSL-6 remote control plates. See page 13.
14. MUSIC CONTROL SWITCHES – determine whether front panel music source controls will remain active when
remote control plates are connected (per-zone). See page 14.
15. MUSIC MUTE – 2-pin 5 mm-pitch screw terminal connector for connection of external emergency muting relay
(e.g., re control panel). See page 14.
16. MAINS – Fused IEC receptacle for AC mains (includes storage for spare fuse). See page 10.
* Only 4 zone outputs on Model Z4MK3 (Items [10] to [14])