CX-A450:
Installation and Operation Manual 5
07-03-05 V3.0
The output load should then be connected between the two positive (HOT) outputs of the
relevant channels (no connection to 0V). You must ensure that the positive wire is
connected to the "first channel" output and the negative wire is connected to the "second
channel" output (see fig 6).
9 Status Indicators
The front panel of the CX-A450 has an array of LED’s that indicate the status of all four
channels (see Fig 7).
The lower green ‘signal’ LED illuminates when a signal is detected, the yellow 'peak' LED will
illuminate when the amplifier’s DCP is operating and the top red ‘protect’ LED indicates that
the protection relay has disconnected the load. Please note that it is normal for all four red
LED's to illuminate for approximately five seconds when the unit is switched on, indicating
operation of the switch-on delay circuitry. The green ‘power’ LED at the bottom right of the
front panel illuminates when the power is switched on.
10 Power Supply Capacity
The CX-A450 has 100mA of current available for optional modules. Exceeding this limit will
cause temporary power supply failure. Use the table below to verify your proposed system
does not exceed this limit.
Module Name Current Required
BOSE® EQ cards: M8, M32, MA12, 402, 502A, 802, MB4, MB24,
502B, 502BEX
12mA
BOSE® EQ cards: LT3202, LT4402, LT9402, LT9702 17mA
BOSE® EQ card: M16 24mA
VCA-5 9mA
11 VCA Modules
A single channel VCA module ‘VCA-5’ is available as a plug-in option
for each of the four channels. When a VCA-5 is installed to a channel
it allows the channel level to be controlled remotely with the optional
RL-1 remote plate.
The circuitry uses the industry standard 'Thats 2150A' VCA providing
very low distortion and up to 90dB attenuation. The VCA module can
be wired to provide muting by using an auxiliary relay connected to a
fire alarm control panel. Contact our technical department for further
details.
12 VCA Module Installation
1. Turn the power off and remove the mains cable
2. Remove the top panel
3. Select the required PCB mounted VCA connector
and remove its jumper (see list below)
CON1 = Channel 1
CON2 = Channel 2
CON3 = Channel 3
CON4 = Channel 4
Fig 7
Fig 8
Fig 9
Kommentare zu diesen Handbüchern